NEC Univerge SV8100 Features And Specifications Manual page 79

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Program Name
Number
10-03-03
ETU Setup (LCA PKG Setup) –
Transmit Gain Level (S-Level)
10-03-04
ETU Setup (LCA PKG Setup) –
Receive Gain Level (R-Level)
15-03-01
Single Line Telephone Basic
Data Setup – SLT Signaling Type
15-03-04
Single Line Telephone Basic
Data Setup – Flashing
Operation
Depends on the connected ancillary device.
Ancillary Device Connection
Description/Comments
Customize the transmit and
receive levels of the CODEC Gain
Types for 500/2500 type single
line telephones.
Customize the transmit and
receive levels of the CODEC Gain
Types for 500/2500 type single
line telephones.
Tell the system the type of dialing
the connected telephone uses.
Enable/Disable Flash for single
line (500/2500 type) telephones.
Assigned Data
1
1~63 (-15.5 +15.5dB)
[default = 32 (0dB)]
1~63 (-15.5 +15.5dB)
[default = 32 (0dB)]
0 = DP
1 = DTMF
(default = 1)
0 = No
1 = Yes
(default = 1)
Issue 5.0
Level
2
3
2 - 53

Advertisement

Table of Contents
loading

Table of Contents