Reference Line
Step
Description
11.
REFLINE Measure Points
<Point ID: S1>
12.
OCUPY (F1) starts collecting data.
13.
If required, check information, for example on the satellites, the
memory or the battery.
14.
When <Auto STOP: No> in CONFIGURE Point Occupation
Settings, STOP (F1) when enough data is collected. At least one
epoch of data must be recorded.
15.
When <Auto STORE: No> in CONFIGURE Point Occupation
Settings, STORE (F1) to store the point information.
The results are displayed on the screen. The values in the fields indi-
cate the position of the point being occupied relative to the reference
line.
It may happen that a point with the same point ID exists in the job. If
the codes and/or attribute values of the new and the existing point do
not match, a screen opens where they can be corrected.