Piston Cooling Nozzle Inspection; Specifications; Service Data; Tightening Torque Specifications - Suzuki AN400 Service Manual

Hide thumbs Also See for AN400:
Table of Contents

Advertisement

1E-6 Engine Lubrication System:
Installation
Install the piston cooling nozzle in the reverse order of
removal. Pay attention to the following point:
NOTE
Before installing, replace the O-ring (1) with a
new one and coat the O-ring with engine oil.

Service Data

Oil Pump
Item
Oil pressure (at 60 °C, 140 °F)

Tightening Torque Specifications

Fastening part
Main oil gallery plug
Oil pump mounting bolt
Reference:
For the tightening torque of fastener not specified in this section, refer to "Tightening Torque Specifications in Section
0C (Page0C-7)".
1
I705H1150010-01

Specifications

Above 30 kPa (0.3 kgf/cm
Below 110 kPa (1.1 kgf/cm
N⋅m
16
10

Piston Cooling Nozzle Inspection

Inspect the piston cooling nozzle in the following
procedures:
1) Remove the piston cooling nozzle. Refer to "Piston
Cooling Nozzle Removal and Installation (Page1E-
5)".
2) Inspect the piston cooling nozzle for clogging. If it is
clogged, clean its oil passage with a proper wire or
compressed air.
3) Install the piston cooling nozzle. Refer to "Piston
Cooling Nozzle Removal and Installation (Page1E-
5)".
Standard
2
, 4.27 psi)
2
, 15.64 psi)
at 3 000 r/min
Tightening torque
kgf-m
lb-ft
1.6
11.5
1.0
7.0
B705H11506021
I705H1150011-01
B705H11507002
Limit
B705H11507003
Note
(Page1E-4)
(Page1E-5)