Suzuki AN400 Service Manual page 281

Hide thumbs Also See for AN400:
Table of Contents

Advertisement

Installation
Install the exhaust pipe/muffler in the reverse order of
removal. Pay attention to the following points:
CAUTION
!
Replace the exhaust pipe gasket (1) and
exhaust pipe connector (2) with the new
ones.
• Install the exhaust pipe gasket (1) and exhaust pipe
connector (2).
2
• Tighten the exhaust pipe bolts (3) to the specified
torque.
Tightening torque
Exhaust pipe bolt (a): 23 N·m (2.3 kgf-m, 16.5 lb-
ft)
• Tighten the HO2 sensor (4) to the specified torque.
Tightening torque
HO2 sensor (b): 48 N·m (4.8 kgf-m, 34.5 lb-ft)
1
I705H11B0007-03
• Apply thread lock to the exhaust pipe joint bolt and
muffler mounting bolts.
(THREAD LOCK CEMENT 1342 or equivalent)
• Tighten the exhaust pipe connecting bolt (5) and
muffler mounting bolts (6) to the specified torque.
I705H11B0008-02
Tightening torque
Exhaust pipe connecting bolt (c): 23 N·m (2.3 kgf-
m, 16.5 lb-ft)
Muffler mounting bolt (d): 23 N·m (2.3 kgf-m, 16.5
lb-ft)
3
(a)
I705H11B0009-02
CAUTION
!
• Be careful not to expose it to excessive
shock.
• Do not use an impact wrench while
installing the HO2 sensor.
• Be careful not to twist or damage the
sensor lead wires.
• Do not apply oil or other materials to the
sensor air hole.
: Thread lock cement 99000–32050
5
(c)
Exhaust System:
1K-3
4
(b)
I705H11B0010-02
6
(d)
I705H11B0011-02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents