Battery Current Leakage Inspection

Inspect the battery current leakage in the following
procedures:
1) Turn the ignition switch to the OFF position.
2) Remove the battery cover (1).
3) Disconnect the (–) battery lead wire.
1
4) Measure the current between (–) battery terminal
and the (–) battery lead wire using the multi-circuit
tester. If the reading exceeds the specified value,
leakage is evident.
Special tool
: 09900–25008 (Multi-circuit tester set)
Battery current (leak)
Under 3 mA
Tester knob indication
Current (
, 20 mA)
CAUTION
!
• In case of a large current leak, turn the
tester to high range first to avoid tester
damage.
• Do not turn the ignition switch to the "ON"
position when measuring current.
5) Reinstall the removed parts.

Repair Instructions

B705H11A06001
I705H11A0002-01
A
I705H11A0003-01

Regulated Voltage Inspection

Inspect the regulated voltage in the following
procedures:
1) Remove the battery cover (1).
2) Start the engine and keep it running at 5 000 r/min
with the dimmer switch turned HI position.
3) Measure the DC voltage between the (+) and (–)
battery terminals using the multi-circuit tester. If the
voltage is not within the specified value, inspect the
generator and regulator/rectifier.
NOTE
When making this test, be sure that the
battery is in fully charged condition.
Special tool
: 09900–25008 (Multi-circuit tester set)
Tester knob indication
Voltage (
)
Regulated voltage
14.0 – 15.5 V at 5 000 r/min
1
( )
4) Reinstall the removed parts.
Charging System:
B705H11A06002
( )
( )
I705H11A0004-01
Battery
( )
DCV
I705H11A0005-01
1J-4