Select Standard Mode
ASCII:
Hexadecimal:
Decimal:
Switches from Page Mode to Standard Mode. In switching from Page
Mode to Standard Mode, data buffered in Page Mode are cleared, the
printing area set by Set Print Area in Page Mode (1B 57) is initialized
and the print position is set to the beginning of the line.
This command switches the settings for the following commands (the
values for these commands can be set independently in Standard Mode
and Page Mode) to those for Standard Mode:
1. Set Right-Side Character Spacing (1B 20)
2. Select 1/6 Inch Line Spacing (1B 32)
3. Set Line Spacing (1B 33)
Standard Mode is automatically selected when power is turned on, the
printer is reset, or the Initialize Printer command (1B 40) is used.
Exceptions:
This command is effective only in Page Mode.
ESC S
1B 53
27 83
Chapter 7: Programming Guide 7-123