Communication Interface Modes

The Configuration Menu gives the user the option of setting the printer to use a USB
communication.
RS–232C Interface Settings [Standard Model]
If the user sets the printer to use an RS–232C serial interface, the Configuration Menu
can be used to set the following RS–232C specific settings:
• Set a baud rate 115200, 57600, 38400, 19200, 9600 baud
• Set the number of data bits to seven or eight
• Set the number of stop bits to one or two
• Enable or disable parity
• Set the printer to ignore data errors or print a "?" upon encountering an error
The settings used will depend on the software the operator is using and the capabilities
of the host computer.