2-18 Chapter 2: Diagnostics and Configuration

Enable or Disable Data Scope Mode

Power Supply Wattage
You can choose between a 48 Watt, 55 Watt or 75 Watt power
supply.
48 Watt Power Supply:
55 Watt Power Supply:
75 Watt Power Supply:
Knife Option
Knife Enabled:Long click
Knife Disabled:
Paper Low Sensor
Paper Low Sensor Enabled: Long click
Paper Low Sensor Disabled: Short click
Printhead Resistance Setting
See "Printhead Resistance" later in this document for more
information.
Note: Press the Paper Feed Button for at least one second to validate
the selection.
For more information about
Setting the printer functions and settings
The Data Scope Mode test prints a hexadecimal dump of all data sent
to the printer: "1" prints as hexadecimal 31, "A" as hexadecimal 41 and
so on. This helps troubleshoot communication problems and runs
during a normal application (after being enabled through printer
configuration).
1 click
2 clicks
3 clicks
Short click
See this section