Chapter 4: Operating an Origin200 System

Separating Two Modules

88
If you wish to separate a two-module system into two individual servers, follow these
steps:
1. Shut down the dual-module system completely. See "Turning the System On and
Off" on page 79.
Be sure to turn off the main power switch at the rear of the system in order to
properly reset the module system controller.
2. Disconnect the CrayLink Interconnect cable from each chassis. See Figure 2-22.
3. Detach the grounding cable from each chassis. See Figure 2-22.
4. Reset the system controller DIP switch on the slave system so that it is a master
module. See Figure 2-21.
5. Reassemble the individual chassis.
6. Attach a system console to the former slave module and boot the system.
The former slave system may not display any output on the system console for up to 5
minutes. This is normal. Allow the system to run through its normal process of
determining what components are installed on the system. Eventually, you will see
output on the system console.