Resetting the System
To reset the system, use this command:
Ctrl+t rst
MSC Error Messages
Many of the commands display the text
prints the error messages shown in Table 4-4 when you enter incorrect commands:
Table 4-4
Module System Controller (MSC) Error Messages
Message
Meaning
err perm
You do not have permission to use this command. You must enter Supervisor
mode with pas in order to use this command.
err cmd
The command you entered is not valid, or you typed the command incorrectly.
err arg
The argument you gave with a command is not valid, or you typed it
incorrectly.
MSC Command Reference
The module system controller (MSC) accepts the commands: shown in Table 4-5.
Table 4-5
Module System Controller (MSC) Commands
Command
Function
aut
Displays 0 if the system is not set to automatically power on and 1 if the system
is set to automatically power on. The default is 0.
aut 0
Do not power on automatically when the master power switch is turned on. The
MSC waits for an explicit power-on command (either from the front panel or via
the pwr command) when the master power switch is turned on. This is the default
setting.
aut 1
Automatically powers on the system (applies power to the logic carrier, PCI
backplane, fans, SCSI devices) after the master power switch is turned on. Does
not wait for the front panel switch to be pressed or for a pwr command via the
AUX port.
Using the AUX Port and Module System Controller Commands
if they succeed. If there is a problem, the MSC
ok