Command Mode
Interface Configuration (Ethernet, port-channel) mode
User Guidelines
There are no user guidelines for this command.
Example
The following example shows how to add VLANs 2 and 5 to 8 to the allowed list of e8.
Console (config)# interface ethernet e8
Console (config-if)# switchport trunk allowed vlan add 2,5-8

5.27.10 switchport trunk native vlan

The switchport trunk native vlan interface configuration command defines the port as a member of the
specified VLAN, and the VLAN ID as the "port default VLAN ID (PVID)". To configure the default VLAN ID,
use the no form of this command.
Syntax
switchport trunk native vlan vlan-id
no switchport trunk native vlan
vlan-id — Valid VLAN ID of the active VLAN.
Default Configuration
VLAN ID=1
Command Mode
Interface Configuration (Ethernet, port-channel) mode
User Guidelines
This command has the following consequences: incoming untagged frames are assigned to this VLAN
and outgoing traffic in this VLAN on this port is sent untagged (despite the normal situation where traffic
sent from a trunkmode port is all tagged).
The command adds the port as a member in the VLAN. If the port is already a member in the VLAN (not
as a native), it should be first removed from the VLAN.
Example
The following example e8, in trunk mode, is configured to use VLAN number 123 as the "native" VLAN.
Console (config)# interface ethernet e8