Configuring port mirroring and monitoring

Configuration notes

Refer to the following rules when configuring port mirroring and monitoring:
TABLE 113
.
Port type
Ingress mirror ports
Egress mirror ports
Ingress monitored ports
Egress monitored ports
NOTE
For PowerConnect B-Series FCX devices , it is possible to configure more than 8 egress ports,
although only the first 8 are operational. This is also true for mirrored VLANs - more than 8 can be
configured, but only the first 8 are operational.
634
Port monitoring and sFlow support:
PowerConnect B-Series FCX devices support sFlow and port monitoring together on the
same port.
If you configure both ACL mirroring and ACL based rate limiting on the same port, then all
packets that match are mirrored, including the packets that exceed the rate limit.
Table 113
lists the number of mirror and monitor ports supported on the Dell PowerConnect
devices. For more information about port regions, refer to
Number of mirror and monitored ports supported
Maximum number supported on...
PowerConnect B-Series FCX
1 per port region
1 per port region
no limit
no limit
You can configure a mirror port specifically as an ingress port, an egress port, or both.
Mirror ports can run at any speed and are not related to the speed of the ingress or egress
monitored ports.
The same port cannot be both a monitored port and the mirror port.
The same port can be monitored by one mirror port for ingress traffic and another mirror port
for egress traffic.
The mirror port cannot be a trunk port.
The monitored port and its mirror port do not need to belong to the same port-based VLAN:
If the mirror port is in a different VLAN from the monitored port, the packets are tagged
with the monitor port VLAN ID.
If the mirror port is in the same VLAN as the monitored port, the packets are tagged or
untagged, depending on the mirror port configuration.
More than one monitored port can be assigned to the same mirror port.
If the primary interface of a trunk is enabled for monitoring, the entire trunk will be monitored.
You can also enable an individual trunk port for monitoring using the config-trunk-ind
command.
For stacked devices, if the ingress and egress analyzer ports are always network ports on the
local device, each device may configure the ingress and egress analyzer port independently.
However, if you need to mirror to a remote port, then only one ingress and one egress analyzer
port are supported for the enitre system.
"About port regions"
PowerConnect B-Series FCX Configuration Guide
on page 306.
53-1002266-01