Displaying The Active Interfaces For A Vrid - Dell PowerConnect B-FCXs Configuration Manual

Powerconnect b-series fcx
Hide thumbs Also See for PowerConnect B-FCXs:
Table of Contents

Advertisement

10
Virtual Switch Redundancy Protocol (VSRP)
TABLE 64
This field...
dead-interval
hold-interval
initial-ttl
next hello sent in
Member ports
Operational ports
Forwarding ports

Displaying the active interfaces for a VRID

On a VSRP-aware device, you can display VLAN and port information for the connections to the
VSRP devices (Master and Backups).
To display the active VRID interfaces, enter the following command on the VSRP-aware device.
PowerConnect#show vsrp aware
Aware port listing
VLAN ID
100
200
Syntax: show vsrp aware
This display shows the following information when you use the aware parameter. For information
about the display when you use the vrid <num> or vlan <vlan-id> parameter, refer to
VRID information"
TABLE 65
This field...
VLAN ID
378
CLI display of VSRP VRID or VLAN information (Continued)
Displays...
The configured value for the dead interval. The dead interval is the number of
seconds a Backup waits for a Hello message from the Master for the VRID before
determining that the Master is no longer active.
If the Master does not send a Hello message before the dead interval expires, the
Backups negotiate (compare priorities) to select a new Master for the VRID.
NOTE: If the value is 0, then you have not configured this parameter.
The number of seconds a Backup that intends to become the Master will wait
before actually beginning to forward Layer 2 traffic for the VRID.
If the Backup receives a Hello message with a higher priority than its own before the
hold-down interval expires, the Backup remains in the Backup state and does not
become the new Master.
The number of hops a Hello message can traverse after leaving the device before
the Hello message is dropped.
NOTE: An MRP ring counts as one hop, regardless of the number of nodes in the
ring.
The amount of time until the Master dead interval expires. If the Backup does not
receive a Hello message from the Master by the time the interval expires, either the
IP address listed for the Master will change to the IP address of the new Master, or
this Layer 3 Switch itself will become the Master.
NOTE: This field applies only when this device is a Backup.
The ports in the VRID.
The member ports that are currently up.
The member ports that are currently in the Forwarding state. Ports that are
forwarding on the Master are listed. Ports on the Standby, which are in the Blocking
state, are not listed.
VRID
Last Port
1
3/2
2
4/1
on page 376.
CLI display of VSRP-aware information
Displays...
The VLAN that contains the VSRP-aware device connection with the VSRP
Master and Backups.
PowerConnect B-Series FCX Configuration Guide