Syntax: show stack

Hitless stacking failover

Hitless stacking failover provides automatic failover from the Active Controller to the Standby
Controller without resetting any of the units in the stack and with sub-second or no packet loss to
hitless stacking-supported services and protocols.
For a description of the events that occur during a hitless failover, refer to
hitless stacking switchover or failover"
For a description this feature's impact to major system functions, refer to
For an example of hitless failover operation, refer to
page 176.
For feature limitations and configuration notes, refer to
limitations"
Enabling hitless failover
To enable hitless failover, enter the following command at the Global CONFIG level of the CLI:
PowerConnect(config)#hitless-failover enable
The command takes effect immediately. Hitless switchover is allowed, and in the event of a failover,
the standby controller will take over the active role without reloading the stack.
Syntax: [no] hitless-failover enable
Use the no form of the command to disable hitless stacking once it has been enabled.