Monitoring Hardware Components; Virtual Cable Testing; Configuration Notes; Command Syntax - Dell PowerConnect B-FCXs Configuration Manual

Powerconnect b-series fcx
Hide thumbs Also See for PowerConnect B-FCXs:
Table of Contents

Advertisement

Monitoring Hardware Components

Table 39
they support.
TABLE 39
Feature
Virtual cable testing (VCT)
Digital optical monitoring
The procedures in this chapter describe how to configure the software to monitor hardware
components.

Virtual cable testing

PowerConnect devices support Virtual Cable Test (VCT) technology. VCT technology enables the
diagnosis of a conductor (wire or cable) by sending a pulsed signal into the conductor, then
examining the reflection of that pulse. This method of cable analysis is referred to as Time Domain
Reflectometry (TDR). By examining the reflection, the Dell PowerConnect device can detect and
report cable statistics such as local and remote link pair, cable length, and link status.

Configuration notes

Command syntax

To diagnose a cable using TDR, enter commands such as the following at the Privileged EXEC level
of the CLI.
PowerConnect#phy cable-diag tdr 1
The above command diagnoses the cable attached to port 1.
When you issue the phy-cable-diag command, the command brings the port down for a second or
two, then immediately brings the port back up.
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
lists the individual Dell PowerConnect switches and the hardware monitoring features
Supported hardware monitoring features
This feature is supported on copper ports only. It is not supported on fiber ports.
The port to which the cable is connected must be enabled when you issue the command to
diagnose the cable. If the port is disabled, the command is rejected.
If the port is operating at 100 Mbps half-duplex, the TDR test on one pair will fail.
If the remote pair is set to forced 100 Mbps, any change in MDI/MDIX may cause the device to
interpret the Multilevel Threshold-3 (MLT-3) as a reflected pulse, in which case, the device will
report a faulty condition. In this scenario, it is recommended that you run the TDR test a few
times for accurate results.
PowerConnect B-Series FCX
Yes
Yes
Chapter
6
189

Advertisement

Table of Contents
loading

Table of Contents