Vsrp Fast Start - Dell PowerConnect B-FCXs Configuration Manual

Powerconnect b-series fcx
Hide thumbs Also See for PowerConnect B-FCXs:
Table of Contents

Advertisement

TABLE 65
This field...
VRID
Last Port

VSRP fast start

VSRP fast start allows non-Dell PowerConnect or non-VSRP aware devices that are connected to a
Dell PowerConnect device that is the VSRP Master to quickly switchover to the new Master when a
VSRP failover occurs
This feature causes the port on a VSRP Master to restart when a VSRP failover occurs. When the
port shuts down at the start of the restart, ports on the non-VSRP aware devices that are
connected to the VSRP Master flush the MAC address they have learned for the VSRP master. After
a specified time, the port on the previous VSRP Master (which now becomes the Backup) returns
back online. Ports on the non-VSRP aware devices switch over to the new Master and learn its MAC
address.
Configuring VSRP fast start
The VSRP fast start feature can be enabled on a VSRP-configured Dell PowerConnect device, either
on the VLAN to which the VRID of the VSRP-configured device belongs (globally) or on a port that
belongs to the VRID.
To globally configure a VSRP-configured device to shut down its ports when a failover occurs, then
restart after five seconds, enter the following command.
PowerConnect(configure)#vlan 100
PowerConnect(configure-vlan-100)#vsrp vrid 1
PowerConnect(configure-vlan-100-vrid-1)#restart-ports 5
Syntax: [no] restart-ports <seconds>
This command shuts down all the ports that belong to the VLAN when a failover occurs. All the
ports will have the specified VRID.
To configure a single port on a VSRP-configured device to shut down when a failover occurs, then
restart after a period of time, enter the following command.
PowerConnect(configure)#interface ethernet 1/1
PowerConnect(configure-if-1/1)#vsrp restart-port 5
Syntax: [no] vsrp restart-port <seconds>
In both commands, the <seconds> parameter instructs the VSRP Master to shut down its port for
the specified number of seconds before it starts back up. Enter a value between 1 – 120 seconds.
The default is 1 second.
Displaying ports that Have the VSRP fast start feature enabled
The show vsrp vrid command shows the ports on which the VSRP fast start feature is enabled.
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
CLI display of VSRP-aware information (Continued)
Displays...
The VRID.
The most recent active port connection to the VRID. This is the port connected
to the current Master. If a failover occurs, the VSRP-aware device changes the
port to the port connected to the new Master. The VSRP-aware device uses
this port to send and receive data through the backed up node.
Virtual Switch Redundancy Protocol (VSRP)
10
379

Advertisement

Table of Contents
loading

Table of Contents