Displaying Cpu Utilization Statistics - Dell PowerConnect B-FCXs Configuration Manual

Powerconnect b-series fcx
Hide thumbs Also See for PowerConnect B-FCXs:
Table of Contents

Advertisement

14
Displaying GVRP information
This display shows the following information for the port.
TABLE 86
This field...
Leave All Received
Join Empty Received
Join In Received
Leave Empty Received
Leave In Received
Empty Received
Leave All Transmitted
Join Empty Transmitted
Join In Transmitted
Leave Empty Transmitted
Leave In Transmitted
Empty Transmitted
Invalid Messages/Attributes
Skipped
Failed Registrations
To display GVRP statistics for all ports, enter the show gvrp statistics all command.

Displaying CPU utilization statistics

You can display CPU utilization statistics for GVRP.
To display CPU utilization statistics for GVRP for the previous one-second, one-minute, five-minute,
and fifteen-minute intervals, enter the following command at any level of the CLI.
520
PowerConnect B-Series FCX stackable switches – <stack-unit/slotnum/portnum>
CLI display of GVRP statistics
Displays...
The number of Leaveall messages received.
The number of Join Empty messages received.
The number of Join In messages received.
The number of Leave Empty messages received.
The number of Leave In messages received.
The number of Empty messages received.
The number of Leaveall messages sent.
The number of Join Empty messages sent.
The number of Join In messages sent.
The number of Leave Empty messages sent.
The number of Leave In messages sent.
The number of Empty messages sent.
The number of invalid messages or attributes received or skipped. This can
occur in the following cases:
The number of failed registrations that have occurred. A failed registration can
occur for the following reasons:
The incoming GVRP PDU has an incorrect length.
"End of PDU" was reached before the complete attribute could be parsed.
The Attribute Type of the attribute that was being parsed was not the
GVRP VID Attribute Type (0x01).
The attribute that was being parsed had an invalid attribute length.
The attribute that was being parsed had an invalid GARP event.
The attribute that was being parsed had an invalid VLAN ID. The valid
range is 1 – 4095.
Join requests were received on a port that was blocked from learning
dynamic VLANs (GVRP Blocking state).
An entry for a new GVRP VLAN could not be created in the GVRP database.
PowerConnect B-Series FCX Configuration Guide