31
Configuration examples
NOTE
When you configure a Backup router, the router interface on which you are configuring the VRID
must have a real IP address that is in the same subnet as the address associated with the VRID by
the Owner. However, the address cannot be the same.
The priority parameter establishes the router VRRPE priority in relation to the other VRRPE routers
in this virtual router. The track-priority parameter specifies the new VRRPE priority that the router
receives for this VRID if the interface goes down. Refer to
"Track ports and track priority"
on
page 1105.
The activate command activates the VRID configuration on this interface. The interface does not
provide backup service for the virtual IP address until you activate the VRRPE configuration.
Alternatively, you can use the enable command. The activate and enable commands do the same
thing.
Syntax: router vrrp-extended
Syntax: ip vrrp-extended vrid <vrid>
Syntax: backup [priority <value>] [track-priority <value>]
Syntax: track-port ethernet [<slotnum>/]<portnum> | ve <num>
Syntax: ip-address <ip-addr>
Syntax: activate