Displaying Gvrp Configuration Information - Dell PowerConnect B-FCXs Configuration Manual

Powerconnect b-series fcx
Hide thumbs Also See for PowerConnect B-FCXs:
Table of Contents

Advertisement

Displaying GVRP configuration information

To display GVRP configuration information, enter a command such as the following.
PowerConnect#show gvrp
GVRP is enabled on the system
GVRP BASE VLAN ID
GVRP MAX Leaveall Timer
GVRP Join Timer
GVRP Leave Timer
GVRP Leave-all Timer
===========================================================================
Configuration that is being used:
block-learning ethe 1/3
block-applicant ethe 2/7 ethe 2/11
enable ethe 1/1 to 1/7 ethe 2/1 ethe 2/7 ethe 2/11
===========================================================================
Spanning Tree: SINGLE SPANNING TREE
Dropped Packets Count: 0
===========================================================================
Number of VLANs in the GVRP Database: 15
Maximum Number of VLANs that can be present: 4095
===========================================================================
Syntax: show gvrp [ethernet <port>]
Specify the <port> variable in the following formats:
This display shows the following information.
TABLE 82
This field...
Protocol state
GVRP BASE VLAN ID
GVRP MAX Leaveall Timer
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
CPU utilization statistics
GVRP diagnostic information
PowerConnect B-Series FCX stackable switches – <stack-unit/slotnum/portnum>
CLI display of summary GVRP information
: 4093
: 300000 ms
: 200 ms
: 600 ms
: 10000 ms
Displays...
The state of GVRP. The display shows one of the following:
GVRP is disabled on the system
GVRP is enabled on the system
The ID of the base VLAN used by GVRP.
The maximum number of ms to which you can set the Leaveall timer.
NOTE: To change the maximum value, refer to
configurable value of the Leaveall timer"
Displaying GVRP information
"Increasing the maximum
on page 510.
14
515

Advertisement

Table of Contents
loading

Table of Contents