Configuring Pfc In A Dcb Map; Pfc Configuration Notes - Dell S6100 Configuration Manual

On system
Hide thumbs Also See for S6100:
Table of Contents

Advertisement

show hardware pfc-nodrop-priority l2-dlf drops stack-unit stack-unit-number port-set port-
pipe
Dell#show hardware pfc-nodrop-priority l2-dlf drops stack-unit 0 port-set 0
---------------------------------------------------
Priority
---------------------------------------------------
0
1
2
3
4
5
6
7
To clear the drop statistics, use the clear hardware pfc-nodrop-priority l2-dlf drops stack-unit stack-
unit-number port-set port-pipe command.
NOTE:
Dell Networking OS Behavior: By default, no lossless queues are configured on a
port.
A limit of two lossless queues is supported on a port. If the amount of priority traffic that you configure to be paused exceeds the two
lossless queues, an error message displays.

Configuring PFC in a DCB Map

A switch supports the use of a DCB map in which you configure priority-based flow control (PFC) setting. To configure PFC parameters,
you must apply a DCB map on an interface.

PFC Configuration Notes

PFC provides flow control based on the 802.1p priorities in a converged Ethernet traffic that is received on an interface and is enabled by
default when you enable DCB. As an enhancement to the existing Ethernet pause functionality, PFC stops traffic transmission for specified
priorities (CoS values) without impacting other priority classes. Different traffic types are assigned to different priority classes.
When traffic congestion occurs, PFC sends a pause frame to a peer device with the CoS priority values of the traffic that needs to be
stopped. DCBx provides the link-level exchange of PFC parameters between peer devices. PFC allows network administrators to create
zero-loss links for SAN traffic that requires no-drop service, while at the same time retaining packet-drop congestion management for LAN
traffic.
On a switch, PFC is enabled by default on Ethernet ports (pfc mode on command). You can configure PFC parameters using a DCB
map or the pfc priority command in Interface configuration mode. For more information, see
As soon as you apply a DCB map with PFC enabled on an interface, DCBx starts exchanging information with a peer. The IEEE802.1Qbb,
CEE and CIN versions of PFC TLV are supported. DCBx also validates PFC configurations that are received in TLVs from peer devices. By
applying a DCB map with PFC enabled, you enable PFC operations on ingress port traffic. To achieve complete lossless handling of traffic,
configure PFC priorities on all DCB egress ports.
When you apply or remove a DCB input policy from an interface, one or two CRC errors are expected to be noticed on the ingress ports for
each removal or attachment of the policy. This behavior occurs because the port is brought down when PFC is configured. When a DCB
input policy with PFC profile is configured or unconfigured on an interface or a range of interfaces not receiving any traffic, interfaces with
PFC settings that receive appropriate PFC-enabled traffic (unicast, mixed-frame-size traffic) display incremental values in the CRC and
discards counters. (These ingress interfaces receiving pfc-enabled traffic have an egress interface that has a compatible PFC
configuration).
NOTE:
DCB maps are supported only on physical Ethernet interfaces.
To remove a DCB map, including the PFC configuration it contains, use the no dcb map command in Interface configuration mode.
DropCount
0
0
0
0
0
0
0
0
Configuring Priority-Based Flow
Data Center Bridging (DCB)
Control.
243