4.8 Security System Configuration

4.8.1 Enable Cross Zoning

Here you determine whether cross zoning will be active or inactive. Cross zoning is a method used to counteract
false alarms - an alarm will not be initiated unless two adjacent zones are violated within a 30-second time limit.
This feature is active only when arming AWAY and only with zone couples from zone No. 18 to 27 (18 and 19,
20 and 21, etc.). You may use any one of these zone couples to create a "cross-zoned" area.
Note: If one of two crossed zones is bypassed (see Para. 4.3.5), the remaining zone will function independently.
Note: Every 2 crossed zones must be of the allowed zone type (Interior, Perimeter, Perimeter follower).
The options are: cross zone ON and cross zone OFF (default).
Cross zoning is not applicable in Entry/ Exit zones and 24h zones (Fire, Emergency, 24h audible, 24h silent).
To Enable Cross Zoning
1.
DEFINE PANEL
2.
01:ENTRY DELAY 1
or
3.
14:CROSS ZONING
4.
cross zone OFF
or
5.
6.
42
Enter the third SMS phone number (including area code, 16 digits max.)
to which pre-selected event types will be reported.
Enter the fourht SMS phone number (including area code, 16 digits max.)
to which pre-selected event types will be reported.
You can now press the
" menu (see step C. To Configure Event Types to be Reported to
tel#
User), or press the
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
Select between "cross zone OFF" and "cross zone ON".
button to take you to the "
button to take you to "
<OK> TO EXIT