5
Adjust the maximum number of messages output to the integrated trace
.
files in New Max(sec).
The default is 0. You can specify a value from 0 to 500 (messages). If you
want to increase the number of messages that are output to the
integrated trace file as much as possible, we recommend that you set this
value to 0.
When you specify a monitoring interval of 0 in 6: Lookout span, the
value set in New Max(sec) will be disregarded.
Also, when you specify a value of 0 for New Max(sec), even if you
specify the monitoring interval in 6: Lookout span, the maximum
number of messages output will not be adjusted.
If you do not want to change the maximum number of messages output,
leave New Max(sec) blank, enter !, and then press the Enter key to
return to the Hitachi Network Objectplaza Trace Library setup menu.
6
Press the Enter key.
.
The new setting is applied and the Hitachi Network Objectplaza Trace
Library setup menu appears again.

Finishing the Hitachi Network Objectplaza Trace Library Settings

To close the Hitachi Network Objectplaza Trace Library setup menu
when you are finished:
1
In the Hitachi Network Objectplaza Trace Library setup menu, type e, and
.
then press the Enter key.
You will be asked to if you wish to save the new settings.
2
To save the new settings, type Yes, otherwise, type No.
.

Applying the Hitachi Network Objectplaza Trace Library Settings

To apply the settings, after you change the amount of integrated
trace information by using Hitachi Network Objectplaza Trace
Library:
1
Log in as a user with root permissions.
.
2
Execute the following command to check the programs using HNTRLib2.
.
In the following example, only HDLM uses HNTRLib2.
# /opt/hitachi/HNTRLib2/etc/hntr2dgetname
Hitachi Dynamic Link Manager
#
3
Stop the programs that are using HNTRLib2.
.
If programs other than HDLM are displayed in step 2, stop the programs,
and then go to step 4. You do not need to stop the HDLM manager.