# /opt/DynamicLinkManager/bin/dlnkmgr view -cha
For details about how to execute the view operation to display the CHA
port IDs, see
To display CHA port information on page 6-60
in
Parameters on page
Example
The following example shows how to place offline all paths connected
to the CHA port whose CHA-port-ID is 00001.
# /opt/DynamicLinkManager/bin/dlnkmgr offline -chaid 00001
KAPL01102-I All the paths which pass the specified CHA port
will be changed to the Offline(C) status. Is this OK? [y/n]:y
KAPL01103-I If you are sure that there would be no problem
when all the paths which pass the specified HBA port are
placed in the Offline(C) status, enter y.
n. [y/n]:y
KAPL01061-I 15 path(s) were successfully placed Offline(C); 0
path(s) were not. Operation name = offline
#
-pathid AutoPATH_ID
Use this parameter to place a single path offline.
Specify the current AutoPATH_ID of the target path, which is displayed by
using the view operation. For details on the view operation, see
(Displays Information) on page
(000001 and 1 indicate the same AutoPATH_ID). Therefore, when the
target AutoPATH_ID is 000000, enter 000000 or 0 for the parameter
value.
AutoPATH_IDs are re-assigned every time the host is restarted. When you
want to add a new LU without restarting the host, AutoPATH_IDs are re-
assigned to each path of the LU when you execute the dlmcfgmgr utility.
Always make sure that you execute the view operation to find the current
AutoPATH_ID of the target path, before executing the offline operation.
-device SCSI-device-name
Use this parameter to place offline all paths connected to the specified
SCSI device.
For SCSI-device-name, specify the value of Device displayed by
executing the view operation as follows:
# /opt/DynamicLinkManager/bin/dlnkmgr view -lu
For details on how to execute the view operation and display the SCSI
device name, see
on page
6-32. Only one case-sensitive parameter value can be specified.
Example
Hitachi Dynamic Link Manager User Guide (for Solaris(R))
6-32.
6-30. Leading zeros can be omitted
To display LU information on page 6-50
Command Reference
Otherwise, enter
view
in
Parameters