Section 2 — Hardware Installation

Network Wiring

42
The module used is specified at the time of order.
All power modules are auto-sensing (120-240 VAC, 50-60 Hz) and are sup-
plied with a main power cable appropriate for the user's geographic loca-
tion. No power switch is present. The AC cord is disconnected to power
down the panel.
WARNING
Do not connect any external power supply other than the approved "JUP-
DCPS" unit supplied by Thomson Grass Valley.
The AC power supply is contained in a module that mounts on the rear of
the panel (Figure 10).
Figure 10. Control Panel Dimensions with Options
The L-S series panels are connected to the CM-4000 (or CM-4400) System
Controller via Ethernet or a Serial connection. Maximum length of a LAN
(Cat5 cable) connection is 329 feet (100 meters). The LAN must be capable
JUPITER L-S and LCD Series Control Panel Instruction Manual