to Jupiter
File Server
Buttons
Button Configuration Overview
Source Button Configuration
Category Button Configuration
JUPITER L-S and LCD Series Control Panel Instruction Manual159
operations, and each Ethernet segment (hub to panel) has a 100 meter limit.
See Figure 85.
Figure 85. LAN only system connections.
CM-4000
System
Controller
(AccuSwitch)
100baseT Jupiter LAN
IP switch
Source button functions are assigned on a panel by creating a Jupiter CP
Output set of type CPESXTND. The CP Input set is assigned to the panel
using the MPK Devices table.
For more information about button configuration, see CP Input and CP
Output Sets
on page
61.
Category buttons exist on some panels, allowing the pre-selection of cate-
gories of Sources or Destinations. The categories can be customized, by cre-
ating a custom Jupiter CP Category set table. This CP Category set would
then be assigned to the CP Input set, or CP Output set, which would in turn
be assigned to the panel using the MPK Devices table.
64 LAN-operated
LCD panels per CM
maximum
LAN 1 (Cat 5 Ethernet) cable.
Max. recommended length per
segment = 100 meters (329 ft)
Buttons