Section 4 — Jupiter System Configuration
Compiling
64
Follow these steps to disable the buttons for a Source or Destination on the
Control panel:
1. Open the CP Output table.
2. Enter the text, "BLANK" in the mnemonic column (see
Figure 28. Output Set Table
3. Enter the number of the desired button in the Button Assignment
column. For example,:
• Buttons 1-32 for the L32 panel.
• Buttons 1-64 for the L64 panel.
• Buttons 1-100 for the S100 panel.
Apply the changes by recompiling the set. The associated button will then
be disabled.
Note
An output called BLANK can be added to the Switcher Output table, without
assigning a physical output. This addition allows the BLANK output to be
selected in the control panel set.
Before the panel(s) can be operated, the edited Jupiter set must be compiled
and the appropriate configuration set made active using the Control
Center. For more information, refer to either the Jupiter CM-4000 Installation
and Operation manual or the Jupiter CM-4400 Installation and Operation
manual.
Following this step, the AccuSwitch control system should start communi-
cating with the panel(s); i.e., the panel(s) will indicate some form of router
status.
JUPITER L-S and LCD Series Control Panel Instruction Manual
Figure
28).