Serial Protocol Table Entries; Mpk Table Entries - GRASS VALLEY JUPITER L - V2.1.0 Instruction Manual

L, s, and lcd series control panels
Table of Contents

Advertisement

Section 5 — Connecting the L-S, LCD Panel

Serial Protocol Table Entries

MPK Table Entries

MPK Devices
MPK
Device
Expansion
Devices
Type
1
CP1
CPES-SER
CP2
CPES-SER
2
CP16
CPES-SER
16
CP17
CPESXTND
17
76
When an L-S or LCD Panels is connected to a Control module (CM-4000 or
CM-4400) serial port (and operated in Serial mode), the Control module
serial port must be configured for "ESCP" protocol using the Serial Pro-
tocol table. The Baud rate should be set at 115K. Use the CPES-SER type for
panels to use up to 98 categories.
Although the L-S or LCD Panels are not actually an MPK-type panel (it has
an on-board microprocessor and does not use the Message Per Key stroke
protocol), the MPK table is used for configuration purposes. An example of
this usage is shown below in
Note
If the phrase, "Follows the same rules as L/S/LCD panels," is shown below
the settings are the same as the ones described in the
figuration
section of this manual.
Figure 38. MPK Devices Table
Pass
Board
Port
Address
Input Sets
word
CM1
1
01
CP_IN
CM1
1
02
CP_IN
CM1
1
16
CP_IN
CM1
01
CP_IN
MPK Devices: This column is used to create a name, up to eight characters
in length, for each L-S or LCD Panels. This name must be unique system-
wide.
Type: Select type CPES-SER for panels wanting to use up to 98 categories.
Note
CPES-SER is the serial equivalent to the CP-ESXTND type.
Expansion: Not used for L-S or LCD Panels (leave unchecked).
Password: A password level will only need to be entered if you wish to
disable the Configuration and Setup menus on the Control panel. See the
Disabling the Configuration and Setup Menus on the Control Panel
page
63.
Board: The name of AccuSwitch Control module connected to this L-S or
LCD Panels. The source of this name is the Jupiter Network Description
table.
Port: The port number that is configured for ESCP to which the panel is
connected. ESCP is defined in the Serial Protocol Table.
JUPITER L-S and LCD Series Control Panel Instruction Manual
Figure
38.
In Panel
Output Sets
Out Panel
CPOUT
CPOUT
CPOUT
CPOUT
Jupiter System Con-
Level Set
Overide Set
Sequence Set
CP_LEV
CP_LEV
CP_LEV
CP_LEV
section on

Advertisement