Table 5-2 Supported Notification Messages (Continued)
Object Label
RMON Events (V2)
risingAlarm
fallingAlarm
Private Traps -
swPowerStatus
ChangeTrap
swFanFailureTrap
swFanRecoverTrap
swIpFilterRejectTrap 1.3.6.1.4.1.202.20.57.84.2.1.0.40 This trap is sent when an
swSmtpConnFailure
Trap
swMainBoardVer
MismatchNotificaiton
swModuleVer
MismatchNotificaiton
C
ONFIGURING
Object ID
1.3.6.1.2.1.16.0.1
1.3.6.1.2.1.16.0.2
1.3.6.1.4.1.202.20.57.84.2.1.0.1
1.3.6.1.4.1.202.20.57.84.2.1.0.17 This trap is sent when the fan
1.3.6.1.4.1.202.20.57.84.2.1.0.18 This trap is sent when the fan
1.3.6.1.4.1.202.20.57.84.2.1.0.41 This trap is triggered if the SMTP
1.3.6.1.4.1.202.20.57.84.2.1.0.56 This trap is sent when the slave
1.3.6.1.4.1.202.20.57.84.2.1.0.57 This trap is sent when the slide-in
SNMP
3 M
V
ANAGEMENT
Description
The SNMP trap that is generated
when an alarm entry crosses its
rising threshold and generates an
event that is configured for
sending SNMP traps.
The SNMP trap that is generated
when an alarm entry crosses its
falling threshold and generates an
event that is configured for
sending SNMP traps.
This trap is sent when the power
state changes.
fails.
failure has recovered.
incorrect IP address is rejected by
the IP Filter.
system cannot open a connection
to the mail server successfully.
board version is mismatched with
the master board version. This
trap binds two objects, the first
object indicates the master
version, whereas the second
represents the slave version.
module version is mismatched
with the main board version.
A
CCESS
5-21
Need help?
Do you have a question about the TigerStack II SMC8848M and is the answer not in the manual?
Questions and answers