NEC V850ES/F 3-L Series User Manual page 434

32-bit single-chip microcontroller
Table of Contents

Advertisement

Chapter 16
Transfer data length
change function
15
Figure 16-2
15
Insertion of 0
Figure 16-3
434
The CSIBn transfer data length can be set in 1-bit units between 8 and 16 bits
using the CBnCTL2.CBnCL3 to CBnCTL2.CBnCL0 bits.
When the transfer bit length is set to a value other than 16 bits, set the data to
the CBnTX or CBnRX register starting from the LSB, regardless of whether the
transfer start bit is the MSB or LSB. Any data can be set for the higher bits that
are not used, but the receive data becomes 0 following serial transfer.
SOBn
10
9
Insertion of 0
(i) Transfer bit length = 10 bits, MSB first
SIBn
12
11
(ii) Transfer bit length = 12 bits, LSB first
User's Manual U18743EE1V2UM00
Clocked Serial Interface (CSIB)
SIBn
0
SOBn
0