Backup Branch; Test Branch; Abort - Paradyne COMSPHERE 3610 User Manual

Data service units
Hide thumbs Also See for COMSPHERE 3610:
Table of Contents

Advertisement

Backup Branch

The Backup (Bckup) branch appears when the
configuration option Network Interface (NetIntf) is set to
AggSw or Forc or a DBM is installed. The DSU provides
an internal aggregate data stream for diagnostics, standby
mode, and framing on the alternate V.35 or EIA-232
interface of Port 1. The aggregate port can be connected
to an external dial backup unit (DBU).
TOP-LEVEL MENU
Local
Remot
Address
Stat
Bckup

Abort

Bkup
Dial
DrBU
Disc
For additional use of the Backup branch, refer to the
TDM/MCMP/Digital Bridge Options Supplement,
Document No. 3610-A2-GB48, and the DBM Options
Supplement, Document No. 3610-A2-GB49.

Test Branch

The Test branch provides extensive testing capabilities
for the DSU, the DDS circuit, the DBM, and the backup
circuit. When the tributary DSU receives a test request
from the control DSU, the DSU aborts any locally
initiated test in progress.
NOTE
Running a test can affect your
application data or may cause
your application session to be
dropped depending upon the
protocol, front-end processor,
and time-out parameters. No
data or acknowledgment
messages will be transmitted
while the test is in progress on
the active core.
3610-A2-GB46-60
Msgs
Test
Confg
Ctrl
Dial
DDS AggSw
Net
496-12971-06
Local
Stat
Bckup
DSU

Abort

Devic
Subn Selective
I
LL
DTE
DL
Port
Port
Select
Select
Abort
Abort allows you to stop a test that is running. The
DSU is not allowed to run any other test until the test in
progress is aborted or completes.
There are two selections for aborting a test:
Subn (Subnetwork) displays only at the control
DSU. This selection terminates any test running at
the control DSU or at a tributary DSU or DBM
associated with the control.
Selective terminates whatever test is in progress at
the local DSU. Does not appear in Remote mode
with MUX Funct set to CBrdg or NetIntf set to
AggSw or Forc.
After selecting either Subn or Selective, the test
terminates and the front panel displays Command
Complete.
December 1996
Front Panel Operation
TOP-LEVEL MENU
Remot
Msgs
Address
Confg
Test
DBM
Lpbk
BERT
DT
EE
Start
Start
Start
Port
Port
Select
Select
Address Address
Run
# Blocks
Tim
RL
Port
Displ
Clr
Select
Address
Ctrl
Lamp
DTone
496-12972-03
3-9

Hide quick links: