Alarms & Traps Options Menu - Paradyne 7110 User Manual

Zhone 7110 network-accessory: user guide
Hide thumbs Also See for 7110:
Table of Contents

Advertisement

Configuration Option Tables
Alarms & Traps Options Menu
A-20
For Alarms & Traps Options, refer to Table A-9. To access the Alarms & Traps
Options screen, follow this menu selection sequence:
Main Menu
Configuration
Alarms & Traps
Table A-9. Alarms & Traps Options (1 of 2)
ASCII Alarm Messages
Possible Settings: Enable, Disable
Default Setting: Disable
Controls the generation and routing of ASCII alarm messages to an ASCII terminal or
printer connected to the Management port. Refer to the
Chapter 6.
Enable – ASCII alarm messages are generated and sent out when the Management
port is configured for Alarms in
The messages are sent out immediately if there is:
– No DCE (e.g., modem or PAD) connected to the Management port and
External Device Commands
Table A-7, or
– An active connection is already established via an external DCE.
If an external device is connected to the Management port with no active
connection, the message control is based on the next option, Alarm & Trap
Dial-Out. External Device Commands must be configured for AT or Other in
Table A-7.
Disable – ASCII alarm messages are not generated or sent.
Alarm & Trap Dial-Out
Possible Settings: Enable, Disable
Default Setting: Disable
When there is no active connection, this option controls whether generating an ASCII
alarm or SNMP trap results in automatic call initiation.
Enable – Automatically places a call via the external device connected to the
Management port.
To send out SNMP traps,
When
Port Use
is set to Net Link in Table A-6, up to ten SNMP traps are queued
at the interface.
The Primary Directory phone number is dialed. Refer to the
Chapter 3.
Refer to the
Call Retry
Disable – Automatic call initiation is disabled and alarm messages are discarded.
SNMP traps are retained until a connection is established.
June 1997
Load Configuration From
Management Port Options,
option is set to Disable in
SNMP Management
must be enabled in Table A-11.
option for handling of incomplete call attempts.
Alarm Messages
section of
Table A-6.
External Device
Options,
Call Setup
section of
7110-A2-GB20-00