Payload Loopback - Paradyne 7110 User Manual

Zhone 7110 network-accessory: user guide
Hide thumbs Also See for 7110:
Table of Contents

Advertisement

Testing

Payload Loopback

5-4
Payload Loopback (PLB) loops the received signal on the network interface back
to the network. Framing CRCs and BPVs are corrected.
Procedure
To run a Payload loopback:
1. Position the cursor at the Start command next to Payload Loopback on the
Network Tests screen.
2. Press Enter.
3. The Start command is changed to Stop. If you want to manually stop the test,
verify that the cursor is positioned at the Stop command.
4. Press Enter. The duration of the test is displayed.
DSU
CSU
ALL 1s
DTE
Payload Loopback cannot be started when any other loopback or Send Pattern
test is already active on the network interface.
June 1997
Network
PLB
Interface
496-15076
7110-A2-GB20-00