Paradyne 7110 User Manual page 148

Zhone 7110 network-accessory: user guide
Hide thumbs Also See for 7110:
Table of Contents

Advertisement

Standards Compliance for SNMP Traps
D-4
The tests that affect the enterpriseTestStart, enterpriseTestStop, and the
variable-binding are different for each particular interface. Diagnostic tests are
only supported on the physical T1 network and user data port interfaces. The
specific tests and variable-bindings are described in the following table:
enterpriseTestStart/Stop
Interface
Variable-Bindings
Physical Sublayer
T1 network
Synchronous User
Data Ports
June 1997
ifIndex (RFC 1573)
ifAdminStatus
(RFC 1573)
ifOperStatus (RFC 1573)
i
fType (RFC 1573)
dsx1SendCode
(RFC1406)
ifIndex (RFC 1573)
ifAdminStatus
(RFC 1573)
ifOperStatus (RFC 1573)
i
fType (RFC 1573)
dsx1LoopbackConfig
(RFC 1406)
ifIndex (RFC 1573)
ifAdminStatus
(RFC 1573)
ifOperStatus (RFC 1573)
i
fType (RFC 1573)
ifTestType (RFC 1573)
ifIndex (RFC 1573)
ifAdminStatus
(RFC 1573)
ifOperStatus (RFC 1573)
i
fType (RFC 1573)
ifTestType (RFC 1573)
Possible Cause
enterpriseTest Start – Any one
of the following tests is active
on the interface:
– Remote Line Loopback
– Send QRSS pattern
enterpriseTest Stop – No
longer has any tests running
on the interface.
enterpriseTest Start – Any one
of the following tests is active
on the interface:
– Line Loopback
– Payload Loopback
enterpriseTest Stop – No
longer has any tests running
on the interface.
enterpriseTest Start – Any one
of the following tests is active
on the interface:
– Repeater Line Loopback
– Send 1-in-8 pattern
– All Monitor Pattern tests
enterpriseTest Stop – No
longer has any tests running
on the interface.
enterpriseTest Start – Any one
of the following tests is active
on the port:
– Local Loopback (DTE)
– Send 511 pattern
– Monitor 511 pattern
enterpriseTest Stop – No
longer has any tests running
on the port.
7110-A2-GB20-00

Advertisement

Table of Contents
loading

Table of Contents