7110-A2-GB20-00
Table C-7. DS1 Near End Group Configuration Table Objects (4 of 5)
Object, OID, Access
dsx1LineStatus
(dsx1ConfigEntry 10 )
1.3.6.1.2.1.1.10.18.6.1.10
read-only
dsx1SignalMode
(dsx1ConfigEntry 11 )
1.3.6.1.2.1.1.10.18.6.1.11
read-only
June 1997
Description
This object specifies the
line (alarm) status of the
network interface.
This object specifies
whether Robbed Bit
Signaling (RBS) is being
used. This object differs
from the MIB definition in
that it is not read/write.
RBS is not supported in this
product.
MIB Descriptions
Setting/Contents
More than one value may be
active at a time.
Supports the following
values:
dsx1NoAlarm(1) – No
alarm present.
dsx1RcvFarEndLOF(2)
– A yellow alarm signal is
being received.
dsx1RcvAIS(8) – An
Alarm Indication Signal
(AIS) is being received.
dsx1LossOfFrame(32)
– An Out Of Frame
condition has persisted
for more than
2.5 seconds (i.e., Red
Alarm).
dsx1LossOfSignal(64)
– A Loss of Signal
condition has persisted
for more than
2.5 seconds (i.e., Red
Alarm).
dsx1LoopbackState(12
8) – The near end of the
network interface is in a
loopback state.
dsx1Other
Failure(4096) – An
Excessive Error Rate
(EER) has been detected
on the network interface.
Supports the following
values:
none(1) – No signaling is
being used on this
interface.
C-19