7110-A2-GB20-00
Table C-16. Generic Interface Test Table Objects (2 of 3)
Object
Description
ifExtnsTestType
(cont'd)
June 1997
MIB Descriptions
Setting/Contents
The following objects use identifiers
to control tests only on the User Data
port interface:
testFullDuplexLoopBack
(wellKnownTests 1) – Starts a
Data Channel Loopback (DCLB)
on the interface.
testLoopDTLB
(wellKnownTests 2) – Starts a
Data Terminal Loopback (DTLB)
on the interface.
testMon 511 (wellKnownTests 4)
– Starts a Monitor 511 test on the
interface.
testSendQRSS
(wellKnownTests 5) – Starts a
Send QRSS test on the interface.
testSend511
(wellKnownTests 6) – Starts a
Send 511 test on the interface.
testSendV54Up
(wellKnownTests 7) – Sends a
V.54 up code to the remote unit.
testSendV54Down
(wellKnownTests 8) – Sends a
V.54 down code to the remote
unit.
testSendFT1Up
(wellKnownTests 9) – Sends a
FTI up code to the remote unit.
testSendFT1Down
(wellKnownTests 10) – Sends a
FT1 down code to the remote unit.