MIB Descriptions
C-32
Table C-16. Generic Interface Test Table Objects (3 of 3)
Object
Description
ifExtnsTestResult
Contains the result of the
(ifExtnsTestEntry
most recently requested
5)
test.
1.3.6.1.3.6.2.1.5
read-only
ifExtnsTestCode
Contains a code providing
(ifExtnsTestEntry
more specific information
6)
about the test result.
1.3.6.1.3.6.2.1.6
read-only
June 1997
Setting/Contents
Supports the following values:
none(1) – No test active.
inProgress(3) – Test is in
progress.
notSupported(4) – Requested
test is not supported.
unAbleToRun(5) – Test cannot
run due to the state of the unit.
Supports the following values:
none (wellKnownCodes 1) – No
further information is available.
Used for send pattern/code and
loopback tests.
inSyncNoBitErrors
(wellKnownCodes 2) – A monitor
pattern (QRSS or 511) test has
synchronized on the pattern and
has not detected any bit errors.
inSyncWithBitErrors
(wellKnownCodes 3) – A monitor
pattern (QRSS or 511) test has
synchronized on the pattern but
has detected any bit errors.
notInSync (wellKnownCodes 4)
– A monitor pattern (QRSS or 511)
test has not synchronized on the
requested pattern.
7110-A2-GB20-00