Configuration Option Tables
A-6
Table A-2. Network Interface Options (3 of 3)
Network Initiated Line Loopback (LLB)
Possible Settings: Enable, Disable
Default Setting: Enable
Allows initiation and termination of the LLB to be controlled by the receipt of
LLB-actuate and LLB-release commands from the network (or remote DSU/CSU).
Enable – Causes the DSU/CSU to enter an LLB (if the DSU/CSU can perform an LLB
in its current state) and to cause an LLB-release command to terminate the LLB.
Disable – Causes the DSU/CSU to ignore LLB-actuate and LLB-release commands
(the DSU/CSU is not in compliance with ANSI T1.403 and AT&T TR 62411).
NOTE:
If this configuration option is enabled, the DSU/CSU recognizes the in-band
LLB-actuate and LLB-release codes specified by AT&T as well as the
bit-oriented FDL messages specified by ANSI (for ESF only).
Network Initiated Payload Loopback (PLB)
Possible Settings: Enable, Disable
Default Setting: Enable
Allows initiation and termination of the PLB to be controlled by the receipt of
PLB-actuate and PLB-release commands from the network (or remote DSU/CSU).
Enable – Causes the DSU/CSU to enter a PLB (if the DSU/CSU can perform a PLB in
its current state) and to cause a PLB-release command to terminate the PLB.
Disable – Causes the DSU/CSU to ignore PLB-actuate and PLB-release commands
(the DSU/CSU is not in compliance with ANSI T1.403 and AT&T TR 54016).
NOTES: – If this configuration option is enabled, the DSU/CSU recognizes the
in-band PLB-actuate and PLB-release codes specified by AT&T as well
as the bit-oriented FDL messages specified by ANSI.
– This configuration option is only available if the network interface
framing is set to ESF.
ANSI Performance Report Messages
Possible Settings: Disable, Enable
Default Setting: Disable
Specifies whether ANSI T1.403 compliant performance report messages (PRMs) are
generated.
Disable – Prevents the DSU/CSU from generating ANSI PRMs.
Enable – Generates and sends ANSI PRMs over the FDL every second.
NOTE:
This configuration option is only available if the framing format is set to
ESF.
Circuit Identifier
Possible Settings: ASCII Text, Clear
Default Setting: [blank]
Uniquely identifies the DS1 circuit.
ASCII Text – Enter a maximum of 15 characters. Refer to the
for valid ASCII characters and control sequences.
Clear – Clears the field.