Table A-7. External Device Options (2 of 3)
Dial-In Access
Possible Settings: Enable, Disable
Default Setting: Disable
Controls external device dial-in access through the Management port.
Dial-In Access option appears when External Device Commands is set to AT.
Enable – Answers incoming calls from an external device and establishes a connection
to a remote terminal or IP network. Refer to the
Management port functions.
Disable – Incoming calls from an external device are not answered.
Connect Prefix
Possible Settings: ASCII Text, Clear
Default Setting: [blank]
The connect prefix and directory phone number are used to establish a connection. The
connection can be initiated by the user or automatically established for dial out of ASCII
alarms or SNMP traps.
Connect Prefix option appears when External Device Commands is set to Other.
ASCII Text – Places a prefix in front of the phone number. Enter a maximum of
20 characters. Refer to the
Clear – Clears the field and sets to none.
Connect Indication String
Possible Settings: ASCII Text, Clear
Default Setting: [blank]
Determines if a connection is established. The DSU/CSU searches the Management
port receive data stream for the connect indication string, and if not received within one
minute, the connection times out. The connection can be initiated by the user or
automatically established to dial out ASCII alarms or SNMP traps.
Connects Indication String option appears when External Device Commands is set
to Other.
ASCII Text – Enter a maximum of 20 characters. Refer to the
for valid ASCII characters and control sequences.
Clear – Clears the field and sets to no string. The port's RTS lead will be used to
determine that a connection has been established.
Escape Sequence
Possible Settings: ASCII Text, Clear
Default Setting: [blank]
When an external device connection is established, the Escape Sequence can be used
to switch an external device to command mode before sending the disconnect
command. Refer to
Escape Sequence Delay (sec)
Sequence.
Escape Sequence option appears when External Device Commands is set to
Other.
ASCII Text – Enter a maximum of 20 characters. Refer to the
for valid ASCII characters and control sequences.
Clear – Clears the field and sets the escape sequence to none.
June 1997
Port Use
ASCII Characters
section.
for delay before and after the Escape
Configuration Option Tables
option in Table A-6 for the
ASCII Characters
section
ASCII Characters
section
A-17