Overview

Port LEDs

7610-A2-GK40-00
TM
This document shows features changed with firmware releases up to
01.05.00 and corrections to the Model 7610 SNMP DSU User's Guide
(7610-A2-GB20-00).
The description of the TXD and RXD LEDs are incorrect in the User's Guide.
TXD – Transmitted Data:
ON
– Receiving all 0s from the DTE.
OFF
– Receiving all 1s from the DTE.
Blinking – User data is being transferred.
RXD – Received Data:
ON
– Sending all 0s to the DTE.
OFF
– Sending all 1s to the DTE.
Blinking – User data is being transferred.