System Options Menu

For System Options, refer to Table A-1. To access the System Options screen,
follow this menu selection sequence:
7110-A2-GB20-00
Main Menu
Configuration
Table A-1. System Options
Self Test
Possible Settings: Enable, Disable
Default Setting: Enable
Controls whether or not the DSU/CSU performs a self-test at power-up and after reset.
Enable – Self-test will be performed at power-up and after a reset.
Disable – Self-test is disabled. The DSU/CSU will still perform a few basic tests (such
as memory and program checksum).
Test Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Allows user-initiated tests to end automatically. Recommend enabling when the unit is
managed remotely through the FDL to avoid the requirement to terminate the test
manually.
Enable – User-initiated loopback and pattern tests end when test duration is reached.
Disable – Tests can be terminated manually from the Network Tests screen. Refer to
the
Running Network Tests
NOTE:
Tests commanded by the DTE or network-initiated tests are not affected by
this test timeout.
Test Duration (min)
Possible Settings: 1–120
Default Setting: 10
Number of minutes for a test to be active before automatically ending.
Test Duration (min) option appears when Test Timeout is enabled.
1 to 120 – Amount of time in minutes for a user-initiated test to run before terminating.
Security Violation Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
Issues an alarm when access to the unit is attempted and fails.
Enable – Alarm generated when a security violation is detected. Refer to the
Trap: authentificationFailure
Disable – No alarm generated for a security violation.
June 1997
Load Configuration From
section of Chapter 5.
section of Appendix D for possible alarm causes.
Configuration Option Tables
System
A-3