DEVO Fl 2E
(2) Pos 0 Down setting
Press UP or DN to move the navigational mark to select item Pos 0 Down, press R or L downward mix value
of Elevator to flap mix will be changed. The mix direction will be revised by changing the sign of plus or minus
before the value. The adjustable range is ±125%.
(3) Pos 1 setting, the setting is same as above.
(4) Throttle stick setting
The switch between Pos 0 and Pos 1 can be realized by setting the position of throttle stick. Press UP or
DN of Throttle Stick to set the position amount of throttle stick. The default setting is Inhibit. The adjustable
range is 0.0-100.0%.
(5) Switch setting
The switch will display the current switch position. Press UP or DN to choose Switch, press ENT to enter
interface of Switch selection, press
UP or DN to choose desired item.
Elevator to Flap Mix
Press ENT to confirm, the desired
item whose left side will be changed
into "1" from "0". If two or more items
are selected, the item And should be
selected, whose left side should be
changed into "1" from "0". Press EXT
after finished it.
Switch
Pos 0
Up
0%
Down
0%
Pos 1
Up
0%
Down
0%
Throttle Stick
Inhibit
Switch
0 An
© Flight Mode 0
oO
FMOD 1
OO
FMOD 2
© Flight Mode 3
CD Flight Mode 4
© Flap Normal
© Flap Midpoint
3.13 Rudder to Aileron/Elevator Mix
This function is used to execute the mix of Rudder to Aileron/Elevator. It will help eliminate waver or shake
caused by rudder stick operation.
Rudder to Aileron/Elevator...
Setting method:
Elevator
Left
Right
Press ENT to enter Main Menu, press UP or DN to make the navigation
Pos 0
Mi l 0%
mark to choose "Function Menu". Press ENT to enter "Function Menu",
then press UP or DN to choose "Rudder to Aileron/Elevator Mix" and press
Pos 1
Aileron
0%
Left
0%
Right
ENT to enter "Rudder to Aileron/Elevator Mix" setting interface.
Pos 0
0%
0%
Pos 1
0%
0%
(1) Elevator setting
Throttle Stick
Inhibit
Switch
Pos 0
(1.1) Elevator Pos 0 Leftward setting
Press UP or DN to make the navigation mark to select "Elevator Pos 0 Left setting" item, and press R or L
to change the value and the Elevator mix amount when operating Rudder leftward .The mix direction will be
revised by changing the sign of plus or minus before the value.The adjustable range is ±125%.
(1.2)
Elevator Pos 0 Rightward setting
Press UP or DN to make the navigation mark to select "Elevator Pos 0 Right setting" item, and press R or L
to change the value and the Elevator mix amount when operating Rudder rightward .The mix direction will
be revised by changing the sign of plus or minus before the value.The adjustable range is ±125%.
(1.3) Elevator Pos 1 setting: refer to "1.1 Elevator Pos 0" setting.
(2) Aileron setting
(2.1) Pos 0 setting: refer to "1.1 Elevator Pos 0"setting.
(2.2) Pos 1 setting: refer to "1.1 Elevator Pos 0"setting.
(3) Throttle stick setting
The switch between Pos 0 and Pos 1 can be realized by the position of Throttle Stick,then press R or L to
change the value or Inhibit.Change the value to set the Thottle Stick position.The default setting is "Inhibit",the
adjustable range is from 0.0 to 100.0%.