Welcome to use the DEVO F12E transmitter
In the main interface press the ENT to enter Model Menu and then press
UP or DN to move the navigational mark to select Model Menu. Press
ENT to enter ModeL Menu. Press UP or DN to select Fixed ID code and
press ENT to enter the Fixed ID code interface.Press UP or DN to select
Status option, Press R or L to change the status to Off. Then press EXT
to exit.
2.14 Sensor setting
Fixed ID
Status
Off
Setting method: press ENT enter to the Main Menu. Press UP or DN to select the Model Menu. Press ENT
enter to Model Menu. Press UP or DN to select sensor press ENT enter to the sensor setting interface. See
the Illustration.
Sensor Setting
Press R or L to select Activate or Inhibit (the default setting is Inhibit),
such as press Activate will includes No Signal Warning,Voltage sensor,
Temperature sensor,GPS receiver setting etc.
(1) No Signal
Press UP or DN to make the navigation mark to choose "No Signal ".
Press R or L to choose " Inhibit" or "Active"(default setting is" inhibit").
If you choose "Active", the Radio will alarm when telemetry signal lost.
Picture as left:
Status
No Signal
Inhibit
Sensor Submenu
Voltage
Temperature
GPS Setting
(2) Voltage setting
There are 3 different types of voltage can be measured.lt includes Interna:VO, External:V1 and V2 which
can be monitored two different external voltage(i.e. battery) respectively.Once the measured voltage is lower
than the setting value, the Radio will alarm.
(2.1) Receiver V0(Internal) PFV(Power Feeding Voltage) Alarmed value can be setted as 3.6-6V
Voltage
Voltage
Internal: VO
Active
Internal: VO
3.6V
External: V1
Inhibit
External: V1
Inhibit
External: V2
Inhibit
External: V2
Inhibit
Voltage setting: press R or L to
activate the VO, the alarm interface
will appear in the interface , please
refer to the Illustration.
Press UP or DN to select the Alarm
Voltage setting, press R or L to set
the value. The range is 3.6-6V. you
can continue to set other items after
you finished.
(2.2)
External:V1
Press UP or DN enter to Extemal:V1
setting interface. Press R or L to
activate the V1, the details refers to
the Illustration.
Press UP or DN to select the Alarm
Voltage setting. Press R or L to set
the value. The setting range is 0.
2-99.9V. you can continue to set
other items after you finished.
Voltage
Voltage
Internal: VO
Inhibit
External: V1 MI:=11 1.
External: V2
Inhibit
Internal: VO
Inhibit
External: V1
0.2 V
External: V2
Inhibit
(2.3)
External: V2 setting can refer to External V1 setting.
Press EXT back to sensor setting interface after you finished.
(3) Temperature sensor
The temperature sensor can measure up to 4 different temperature(i.e.motors).You can choose Celsius or
Fahrenheit.The alarmed value can be setted to 4 different temperature.Once the measured value is higher
than the setting value, the radio will alarm.The Alarm Temperature value can be setted as -20-220°C or
-4.0-428.0° F.