Point-Right Setting: Press UP or DN to choose "Point-Right". Press R
or L to Inhibit or Active. If need to adjust please Active it. There will be
expanded value adjustment item. Press UP or DN to choose "0%" If
need to adjust the value, press L (0% means no adjusting). A minus
value means the amending direction is downward; press R to adjust value
(0% means no adjusting). A plus value means the amending direction
is upward. The adjustable range is 100%.
Press UP or DN, there will be setting for Point-1, Point-2, Point-3, Point-
Left, Point>Left, refer to the setting method as above. Press EXT after
finished it.
Balance
Channel
Aileron
Point < Right
Active
0%
Point - Right
0%
Point - 1
Inhibit
3.9 Gyro Sensor
This function offers the gain adjustment for gyro sensor, which can be manually set through D/R switches or
Flight mode switch, and also is possible to be automatically switched among various gains through flight mode
switch. (The flight mode should be activated. Refer to "2.9 Device Select").
Setting method:
Gyro Sensor
Press ENT to enter Main menu; Press UP or DN to choose Function menu.
Press ENT to enter Function menu; Press UP or DN to choose Gyro
Sensor setting, press ENT to enter the setting interface of Gyro Sensor
setting.
(1) Manual Setting
(1.1) Manual Setting:
Under Gyro setting interface, press UP or DN to choose Mode, press R or L to select Manual setting or
Automatic Setting ( Automatic setting can be activated if Flight mode is act, refer to "2.9 Device selection").
Choose "Manual Setting"
(1.2) Channel:
The default setting is AUX 2. It is possible to alter into other channels in the interface of Device Output (Refer
to "2.10 Device Output").
(1.3) Switch selection:
Under Gyro setting interface, press UP or DN to choose Switch, press R or L to expand into six articles: FMOD
SW, MIX SW, ELEV D/R, AILE D/R, and RUDD D/R, GEAR SW. Choose the desired switch for Manual control.
Pos 0
Mode
Manual
Channel
AUX2
Switch
ELEV D/R
Pos 0
50.0%
Pos 1
50.0%
(1.4) Sensitivity Setting
If choose 3 switches,there are "Pos 0","Pos 1" and "Pos 2", then set the sensitivity individually; If choose 2
switches, there are "Pos 0" and "Pos 1" , then set the sensitivity individually.
Gyro Sensor
Pas 0 ti
Display the current switch position
Mode
Manual
Channel
AUX2
Switch
ELEV D/R
Pos 0
50.0%
Pos 1
50.0%
(1.4.1) Status:
Turn the setting gyro control switch, the status items will display the
current switch status position.
(1.4.2) Pos 0:
Press UP or DN to move the navigational mark to Pos 0 and press R
or L to increase or decrease, respectively, the value.If the gyro used has
two modes of NOR and AVCS, NOR will be activated when the value
is less than 50.0%. In NOR mode, the smaller the value is, the bigger
the gyro sensor sensitivity will be. The factory setting is 50.0%.
(1.4.3) "Pos 1"," Pos 2" are the same setting way as above "Pos 0".
Gyro Sensor
2
Pos 0
Mode
Manual
Channel
AUX2
Switch
ELEV D/R
Pos 0
50.0%
Pos 1
50.0%
DEVO F 1 2 E — 70