Welcome to use the DEVO F12E transmitter
DEVO Fl 2E
Program Mix 1
Master
Elevator
Slave
Elevator
Position
Pos 0
Exponential
Off
Point
Point - 1
Status
Active
Output
0%
0%
0%
(2.8) Throtte Stick
The switch between Pos 0 and Pos 1 can be realized by setting the
position of throttle stick. Press UP or DN to make navigation mark to
select "throttle stick" setting, press R or L to change the value or inhabit.
Change value can set throttle stick postion.The default setting is "inhabit".
The adjustable range is from 0.0% to 100.0%
Program Mix 1
2
Position
Pos 0
Exponential
Off
Point
Point - 1
Status
Active
Output
0%
Throttle Stick
Inhibit
Switch
Pos 0
0%
0%
(2.7) output setting
When the Status option is Active, the Output option will be listed.Press
UP or DN to move the navigational mark to Output. Press R or L to
increase or decrease, respectively, the output amount. It is possible to
reverse the mix direction by changing the plus or minus sign before the
amount. The adjustable range is ±100%.
(2.9) Switch Selection
When the item Throttle Stick is set in Inhibit, it is possible to switch between Pos 0 and Pos 1 by Switch.
Press UP or DN to select "Switch". Press ENT to enter Switch interface press UP or DN to choose desired
item. Press ENT to confirm, the
desired item whose left side will be
changed into "1" from "0". If two or
more items are selected, the item
And should be selected, whose left
side should be changed into "1" from
"0". Press EXT after finished it.
3.18 Monitor
Program Mix 1
Switch
Position
Pos 0
Exponential
Off
Point
Point - 1
Status
Active
Output
0%
Throttle Stick
Inhibit
Switch
0%
0%
0 And
© Flight Mode 0
OO
FMOD 1
oO
FMOD 2
© Flight Mode 3
© Flight Mode 4
© Flap Normal
© Flap Midpoint
This function can display the current status and positions of all the channels' outputs, and check the current
working status of each channel.
Monitor
2
Elevator 0
Gyro 0
Aileron R 1
AUX3 -100
Throttle L100
AUX4 -100
Rudder R 34
AUX5 -100
Gear -100
AUX6 +100
Flap D100
AUX7 +12
3.19 Fail safe
Press ENT to enter Main Menu, and then press UP or DN to move the
navigational mark to select Function Menu.Press ENT to enter the Function
Menu and then press UP or DN to select servo Monitor and press ENT
to enter the monitor interface for checking the current working status of
each channel. Press EXT to exit .
There are two possibilities for use if the transmission signal is under abnormal condition. The first one is to
lock the last action data received; the second one is to execute the pre-set data which is pre-set. The default
setting is Servo Hold.
Fail Safe
g
Setting method:
Press ENT to enter the Main Menu, and then press UP or DN to move
the navigational mark to select Function Menu. Press ENT to enter the
Function Menu then press UP or DN to select Fail Safe and press ENT
to enter the Fail Safe interface.Take the item Elevator as an example
to explain.
Elevator
Servo Hold
Aileron
Servo Hold
Throttle
Servo Hold
Rudder
Servo Hold
DEVO Fi 2E — 80

Advertisement

Table of Contents
loading

Table of Contents