Pitch Curve - devention DEVO F12E User Handbook Manual

Hide thumbs Also See for DEVO F12E:
Table of Contents

Advertisement

g
Pitch Curve
g
Pitch Curve
Flight Mode
Exponential
Point
Normal Mode
Off
Point - L
All Servos Hold?
Warning
Ok
Cancel
Output
-100%
-100% -100%
cleention
DEVO F12E
Welcome to use the DEVO F12E transmitter
(2) Aileron Mix Adjustment
In the interface of Swash Mix,press UP or DN to choose the navigation mark of Aileron Setting item. Press
R button to increase the rate and L to reduce. If reversed direction, it is available to chang through the "+" or
"-" mark. The adjustable rate is ± 125%. After finish the settings, press DN to set others.
(3) Elevator mix adjustment
The function is based on the three or more servos which is choosed(refer to the 2.11 Swash Type).The setting
method is same as above.
(4) Pitch Mix Adjustment
The function is based on the two or more servos which is choosed(refer to the 2.11 Swash Type).The setting
method is same as above.
(5) Exponential Curve
This function can execute the exponential changes, which are set at Dual
Rate and Exponential in Function Menu when it is started. If Off is selected,
the exponential curve will be changed in the form of fold line.
Setting method:
Press UP or DN to touch the navigation mark of Exponential to expand
two options: Off and On. the default setting is Off. On is recommended.
Please press EXT key to exit after finished.
Swash Mix
3 Servos 120'
Aileron
+60%
Elevator
+60%
Pitch
+60%
Exponential
3.13 Pitch Curve
7-point adjustment method is allowed to set up all the pitch curves, respectively, in each flight mode, which
includes Normal Mode, Stunt 1, Stunt 2, Stunt 3, Stunt 4, and Throttle Hold. The Flight Mode Extra Switch in
Device Select should be previously chosen. Refer to "2.9 Device Select".
Setting method:
Press ENT to enter Main menu. Press UP or DN to move navigation mark to select Function Menu. Press
ENT to enter function menu. Press UP or DN to select Pitch Curve. And press ENT to enter ENT to enter
function menu. Press UP or DN to
select Pitch Curve, press ENT to
enter Pitch Curve interface, there is
"All servos hold?", press ENT to
confirm with OK for all the servos will
be locked at the current states. Or
use UP or DN to Cancel for Unlocked.
Enter the next interface after
confirmed OK or Cancel.
(1) Flight mode
Press UP or DN to select the Flight Mode at the interface of Pitch Curve, and then move the switch of flight
mode, the state of flight mode will be shown. The Pitch Curve can be set at the current state. There are
"Normal Mode", "Stunt 1", "Stunt 2" ,"Stunt 3", "Stunt 4" and "throttle hold" 6 flight modes.The "Normal Mode"
is made as an example for your referrence.
Display present flight mode
(2) Exponential
Press UP or DN to choose the setting item of Pitch Curve .There are
ON or OFF option when you press the R or L buttoms.The Curve Pitch
will become round if the On buttom is choosen. If you don't adjust the
Pitch Curve Funtion, then choose Off buttom.
Pitch Curve
Flight Mode
Normal Mode
Exponential
Off
Point
Point - L
Output
-100%
-100% -100%
DEVO F1 2E —39

Advertisement

Table of Contents
loading

Table of Contents