Gyro Sensor; Governor - devention DEVO F12E User Handbook Manual

Hide thumbs Also See for DEVO F12E:
Table of Contents

Advertisement

Gyro Sensor
8 g
Normal Mode
Mode
Channel
Switch
Normal Mode
Pos 1
Pos 2
Pos 3
Automatic
AUX2
MIX SW
50.0%
50.0%
50.0%
50.0%
Gyro Sensor
Normal Mode
Mode
Channel
Switch
Normal Mode
Pos 1
Pos 2
Pos 3
Automatic
AUX2
MIX SW
50.0%
50.0%
50.0%
50.0%
Gyro Sensor
0
Mode
Channel
Switch
Normal Mode
Pos 1
Pos 2
Pos 3
Normal Mode
Automatic
AUX2
MIX SW
50.0%
50.0%
50.0%
50.0%
clXention
Welcome to use the DEVO F12E transmitter
DEVO F 1 2 E
(1.4) Sensitivity Setting
If choose 3 switches,there are "position 0","position 1" and "position 2",then set the sensitivity individually; If
choose 2 switches,there are "position 0" and "position 1" , then set the sensitivity individually.
(1.4.1) Pos 0
Turn the choosed GYRO Control Switch, make the status display present
switch status "Pos 0" . Press UP or DN to choose "Pos 0", press R or L
to increase/decrease value individually. If the GYRO have "NOR" mode
and "AVCS" mode, when the value lower than 50%, it is "NOR"mode.
The lower of the value is, the bigger of the GYRO sensitivity becomes.
The factory default value is 50%.
Gyro Sensor
2
Pos
Mode
Manual
Channel
AUX2
Switch
MIX SW
Pos 0
50.0%
Pos 1
50.0%
Pos 2
50.0%
(1.4.2) "Pos 1"," Pos 2" are the same setting way as above "Pos 0".
(2) Automatic setting
(2.1) Automatic Setting
In the Gyro Sensor interface, press UP or DN to choose "mode" project
set, press R or L to selectable sets ("Manual set" and "Automatic set").Then
choose "Automatic" option.
(2.2) Channel
The original channel is "AUX2",if you want to change to other channels
control,you can choose from "output"set.(refer to "2.10 output").
(2.3) Switch: There is no use in the Automatic Setting.
Display present flight mode
(2.4)
Status
Turn the Switch "flight mode"or "Throttle hold", the status set display
present flight mode position.There are Normal Mode, Stunt 1, Stunt 2 ,
Stunt 3 ,Stunt 4, Throttle hold sets. For Stunt 3 ND Stunt 4, Flight Mode
Extra Switch should be activated in Device Select as well as Throttle
Hold Switch is set as RUDD D/R.(refer to "2.9 Device Select")
(2.4.1) Normal Mode
Press UP or DN to choose "Normal Mode" project set, press R or L can
increase or decrease the value individually.lf the GYRO have "NOR"mode
and "AVCS"mode, when the value is lower than 50%,it is "NOR"mode. the
lower of the value is ,the bigger of the GYRO sensitivity becomes. The
factory default value is 50%.
(2.4.2) Stunt 1, Stunt 2, Stunt 3, Stunt 4, throttle hold settings refer to
"Normal Mode". After finishing the set, press EXT to exit.
3.9 Governor
Before setup this function, "Governor" should be set and activated in "output" interface. (Refer to 2.10 Output)
It is possible to set Governor control rate in various flight modes seperately. Please setup the Governor for
the desired retation speed. The transmitter display data is only for percentage reference. The real rotation
speed refer to Governor.
Setting method:
Press ENT to enter Main Menu; Press UP or DN to move make navigation mark to select Function Menu.
Press ENT to enter Function Menu; Press UP or DN to choose Governor then through the ENT key to the
Governor setting interface, which display the status and channels; Press UP or DN can see the Normal Mode,
Stunt 1, Stunt 2, Stunt 3, Stunt 4, Throttle Hold and so on .
DEVO F 1 2 E — 36

Advertisement

Table of Contents
loading

Table of Contents