Sensor Setting - devention DEVO F12E User Handbook Manual

Hide thumbs Also See for DEVO F12E:
Table of Contents

Advertisement

Fixed ID
g
Fixed ID
Are you sure?
Fixed ID
g
Fixed ID
ID Match
Voltage
g
Voltage
g
Internal: VO
ME
Internal: VO
I
3.6V
External: V1
Inhibit
External: V1
Inhibit
External: V2
Inhibit
External: V2
Inhibit
cle(Lnlion
DEVO F12E
Welcome to use the DEVO F12E transmitter
(2) Fixed ID cancellation
Insert the assorted BIND PLUG into the output terminal of BATT before the
receiver is powered on, and then plug 5V DC power into other output terminal.
The red light of receiver will flash slowly. This means the fixed ID code has
been cancelled. Pull out bind plug. DEVO F12E also needs to make relative
cancellation and revision after the fixed ID in receiver is cleared out.
Fixed ID
2
Status
i
In the main
interface press the ENT to enter Model Menu and then press
UP or DN to move the navigational mark to select Model Menu. Press
ENT to enter ModeL Menu. Press UP or DN to select Fixed ID code and
press ENT to enter the Fixed ID code interface.Press UP or DN to select
Status option, Press R or L to change the status to Off. Then press EXT
to exit.
2.14 Sensor setting
Setting method: press ENT enter to the Main Menu. Press UP or DN to select the Model Menu. Press ENT
enter to Model Menu. Press UP or DN to select sensor press ENT enter to the sensor setting interface. See
the Illustration.
Sensor Setting
Press R or L to select Activate or Inhibit (the default setting is Inhibit),
such as press Activate will includes No Signal Warning,Voltage sensor,
Temperature sensor,GPS receiver setting etc.
(1) No Signal
Press UP or DN to make the navigation mark to choose "No Signal ".
Press R or L to choose " Inhibit" or "Active"(default setting is" inhibit").
If you choose "Active", the Radio will alarm when telemetry signal lost.
Picture as left:
Status
No Signal
Inhibit
Sensor Submenu
Voltage
Temperature
GPS Setting
2) Voltage setting
There are 3 different types of voltage can be measured.lt includes Interna:VO, External:V1 and V2 which can
be monitored two different external voltage(i.e. battery) respectively.Once the measured voltage is lower than
the setting value, the Radio will alarm.
(2.1) Receiver VO(Internal) PFV(Power Feeding Voltage) Alarmed value can be setted as 3.6-6V
Voltage setting: press R or L to
activate the VO, the alarm interface
will appear in the interface , please
refer to the Illustration.
Press UP or DN to select the Alarm
Voltage setting, press R or L to set
the value. The range is 3.6-6V. you
can continue to set other items after
you finished.
DEVO F 1 2 E — 28

Advertisement

Table of Contents
loading

Table of Contents