Swash Type; Power Amplifier; Fixed Id - devention DEVO F12E User Handbook Manual

Hide thumbs Also See for DEVO F12E:
Table of Contents

Advertisement

V
1 Servo Normal
2 Servos 180°
3 Servos 120'
3 Servos 140°
3 Servos 90°
4 Servos 90°
Power Amplifier
+20 dBm
+15 dBm
+10 dBm
+5 dBm
0 dBm
-5 dBm
cleention
DEVO F12E
Welcome to use the DEVO F12E transmitter
2.11 Swash Type
The swash type is grouped into six options: 1 Servo Normal, 2 Servos 180°, 3 Servos 120°,3 Servos 140°, 3
Servos 90° and 4 Servos 90°.
Swash Type
Press ENT to enter Main Menu, press UP or DN to move navigation mark
to Model Menu. Press ENT to enter Model Menu. Press UP or DN to select
Swash Type and press ENT to enter Swash Type interface.
Press UP or DN to choose the required "Swash type", press ENT to
confirm, the corresponding items will have the"y" mark in front of the
items. Press EXT to exit after finishing.
2.12 Power Amplifier
The transmission output power of DEVO F12E is adjustable. It is divided into six grades from small to big.
The lower the transmission output power transmits, the shorter the radio range is, and the longer the stand-
by time will be, the higher the transmission output power, the farer the radio range, and the shorter the stand-
by time. Choose the appropriate transmission output power according to the actual situation.
Press ENT to enter Main Menu, press UP or DN to move navigation mark to Model Menu. Press ENT to
enter Model Menu. Press UP or DN to select Power Amplifier and press ENT to enter Power Amplifier interface.
Press UP or DN to choose the desired output power value. Press ENT
to confirm then the corresponding items will have "V"mark in front of
the items.
After the setting, press EXT to exit.
Grade 6
Grade 5
Grade 4
Grade 3
Grade 2
Grade 1
20dBm
15dBm
10dBm
5dBm
OdBm
-5dBm
2.13 Fixed ID
This setting will bind DEVO F12E with its receiver in a unique corresponding relationship. It will greatly speed
up the time of automatic binding when DEVO F12E powered on.
(1) Setting for fixed ID
The setting for fixed ID should be under the status that automatic ID binding is successfully finished. Below
is the setting method.
Press ENT to enter the main Menu and press UP or DN to move the navigational mark to select Model menu.
Press ENT to enter Model Menu. Press UP or DN to select Fixed ID and press ENT to enter the Fixed ID
setting interface.(Fig. 1)
If you want to activate the fixed ID settings, press R or L to change the status from off to ON. A series of
random digits will be shown below after change to On. (Fig. 2)
Press UP or DN to choose the ID code setting, press R or L to choose the digits,press UP or DN to move to
the next code setting . there are 6 digits can be setted. (Fig. 3)
Fixed ID
g
Status
(Fig. 1)
Fixed ID
g
Status
ID Code
129965
(Fig. 2)
Fixed ID
g
Status
On
ID Code
29965
(Fig. 3)
Press ENT key after the new ID has been setted. An inquiry interface of "Are you sure?" pop up. "ID Code
Matching ... ..." will be shown after press ENT. After matching, the interface will be returned to Model Menu.
DEVO F 1 2 E — 27

Advertisement

Table of Contents
loading

Table of Contents