(2) Down setting
Once the values for UP are set press DN to show the current MIX setting for DOWN (ELEV input to fly backwards) .
In the interface of Mix to Throttle, press UP or DN to move the navigation mark to select Down item. Press R or L to
increase or decrease, respectively, the mix amount when moving the throttle stick downwards. A positive MIX value
means that as ELEV channel output value is decreased (when flying backwards), the THRO value will also be
increased automatically. A negative MIX value means that as ELEV channel output value is decreased (when flying
backwards), the THRO value will be decreased automatically. The available range of adjustment is ±125%.
(3) Switch Selection
In the interface of Mix to Throttle,press UP or DN to move the navigation mark of Switch and press ENT to
enter Switch interface. There are Always on, Normal Mode, Stunt Mode options. Press UP or DN to select
the Switch option. Press ENT to make a ". / " mark to the choosed switch. Press EXT to the interface of Mix
to Throttle. Puress DN to setup the Aileron or Rudder.
(4) Aileron or Rudder Mix to Throttle setup can be referred to Elevator setting.
Press EXT after finished.
Note:
(1) Before flight, please confirm: All above amount of mix to throttle is proper enough to ensure a good flight.
And make sure all the actions in different flight mode are normal.
(2) The function is in spare when governor is working.
3.8 Gyro sensitivity
This function offers the gain adjustment for gyro sensitivity, which can be manually set through HOLD
switches, and also is possible to be automatically switched among various gains through flight mode switch.
Setup:
Press ENT to Main Menu, use UP or DN to choose function
menu. Press ENT to function menu.Press UP or DN to choose
Gyro Sensor, then press ENT to Gyro Sensor interface.
(1) Manual Setting
(1.1) Manual Setup
In the Gyro Sensor interface, press UP or DN to choose
Mode, there are Manual set and Automatic set for selectable choice. Press R or L to select Manual option.
(1.2) Channel
The factory default channel is AUX2, the Output set offer the function to change other control channels (Refer
to "2.10 Output").
(1.3) Switch Select
In the interface of Gyro Sensor, press UP or DN to choose SWITCH,press ENT to SWITCH, there are FMODSW
and HOLDSW for selectable sets, press R or L to choose the desired switch for Manual control.
(1.4) Sensitivity Setup
There are Position 0 and Position 1 two selection which can set the sensitivity individually.
(1.4.1) POS 0
Choosing MANU and then pressing ENT shows the SWITC status. This indicates the switch to which GYRO
sensitivity settings are assigned. Default is HOLD SW.
-
GYRO value. The first POS setting displayed is POS 0,
I
pressing DN again displays POS 1 . To change the value I
HOLD
Vii
use the R or L buttons. The GYRO has two modes of
operation; AVCS or NOR. When the value is set greater
Id I LI
than 50% AVCS will be activated. AVCS is also knows as
Heading Hold or HH gyro. The bigger the value the bigger
the gyro sensor heading gain becomes, or the harder it tries to maintain the heading.
The NOR mode, also known as RATE mode, is activated by setting the value to less than 50%. The smaller the
value the greater the gyro sensor rate gain becomes, or the harder it tries to maintain a constant YAW rate.
Once POS 0 is set as desired, use DN to set POS 1 setting as required. Typical values are POS 0 = 75%,
POS 1 = 50% . Default values are all 50%.
r pnsor
Fit
NA
0
d e
Channel
r0
Sensor
Pressing DN displays the switch position and assigned