Trigger Control - IAI SP-20000M-PMCL User Manual

Cmos digital progressive scan monochrome and color camera with mini camera link interface
Table of Contents

Advertisement

SP-20000-PMCL User Manual (Ver. 3.1)

Trigger Control

The camera allows Frame Start trigger controls to be performed via external trigger signals.
The Frame Start trigger allows exposure control via the trigger signal inputs.
Trigger Mode can be selected in Trigger Selector. On this camera, the trigger mode is limited to Frame
Start. However, it is possible to operate as shown below:
Trigger
Trigger
Selector
Mode
Off
Off
Frame Start
On
On
On
Trigger Selector
Selects the trigger operation. On this camera, only Frame Start is available.
Trigger Mode
Select either free-running operation or external trigger operation.
OFF: Free-running operation
l
ON: External trigger operation
l
Trigger Source
Select the trigger source to be used for trigger operation.
0: Low (Default), 1: High, 2: SoftTrigger, 8: PulseGenerator0, 9: PulseGenerator1, 10: PulseGenerator02,
l
11: PulseGenerator03, 12: TTL_In1, 13: CL_CC1_In, 14: Nand0, 15: Nand1, 16: TTL_In2, 17: LVDS_In
Note: On this camera, GPIO port is located on the AUX interface (Hirose 10P). In this GPIO. Line
10 and Line 11 are available.
Exposure
Trigger
JAI Custom Trigger
Mode
Option
Off
Off
Timed
Off
Timed
Off
Trigger
Off
Width
Timed
PIV
Name
Self running operation with the maximum exposure time
Continuous Trigger
Continuous Trigger
Self running operation with a user-set exposure time.
Externally triggered operation with a user-set exposure
EPS Trigger
Externally triggered operation with a pulse width exposure
PWC Trigger
PIV Trigger
- 68 -
Description
per the frame rate
time
time
Externally triggered operation for PIV
Main Functions